Part No.: URP09xFIO Indoor/Outdoor Cable
Fiber Optic Cable Cable Cross Section
x is Number of Cores & x<=12

Unitube Fiber Optic Cable
SM, 2~12C,
Flame-Retardant Jacket,
Rodent protect,
All Dielectric
Application :
Indoor/Outdoor
Cable Construction & Description
   
Fiber Coloring : UV Curable Acrylic Color Ink
No. of Tube : 1Tubes
No. of fiber/Tube : Max. 12 Fibers
Loose Tube Material : PBT
Filling compound (Tube) : Thixotropic Jelly
Strength Member : Aramid Yarn
Outer Sheath : Flame-Retardant PVC
  Nom.1.0mm Thick.
Cable Marking : Cable type, Fiber Counts
Name of Manufacturer
Year of Manufacturing,
Cable Length in meter
Cable Outside Diameter : Nom. 6.0mm
Cable Weight : Approx. 35kg/km
Packing : Export Wooden Drum
 
Optical Fiber Performance
 
1.Optical & Geometrical Performance
     
  Mode Field Diameter : 9.3 ± 0.5μm at 1310nm
  Mode Field Concentricity Error : ≤ 0.8μm
  Cladding Diameter : 125 ± 1μm
  Cladding Non-Circularity: ≤ 1%
  Coating Diameter : 245 ± 10μm
  Coating Non-Circularity Error : ≤ 6%
  Attenuation Coefficient : ≤ 0.36dB/km at 1310nm
    ≤ 0.22dB/km at 1550nm
  Chromatic Dispersion : ≤3.5ps/nm/km at1285~1330nm
    ≤18ps/nm/km at 1550nm
  Cut-off Wavelength (λcc) : ≤ 1260nm
  Zero Dispersion Wavelength : 1300~1322nm
  PMD Coefficient : ≤ 0.2ps/√km
  Point Discontinuity : ≤ 0.05 dB at 1310 & 1550nm
  Effective Group Index of : 1.4677 at 1310nm(Typical)
  Refraction (Neff) : 1.4682 at 1550nm(Typical)
 
2.Mechanical & Environmental Performance
 
  Proof Test Level : ≥ 0.69 GPa(≥100kpsi)
  Macro bending : ≤ 0.05 dB at 1550nm
     (at 75mm dia. x100 turns)
  Temperature Dependence : ≤ 0.05 dB/km at 1550nm
     (-60°C to 85 C)
  Damp Dependence: ≤ 0.05 dB/km at 1550nm
     (+80°C,85%RH for 30Days)
  Water soak Dependence : ≤ 0.05 dB/km at 1550nm
     (+20°C for 30Days)
 
Identification of optical fiber & Loose Tube
 
Optical Fiber Loose Tube
1 Blue 7 Red White
2 Orange 8 Black
3 Green 9 Yellow
4 Brown 10 Violet
5 Grey 11 Pink
6 White 12 Aqua
 
Mechanical & Environmental Performance
 
Item Reference  Test Condition Acceptance Criteria
Tensile Strength IEC 794-1-E1 Long Term : 300N, Short Term : 1000N Attenuation Increase:≤0.1dB
Crush IEC 794-1-E3 Loading : 1000N/100mm Attenuation Increase:≤0.1dB
Impact IEC 794-1-E4 Loading : 1N.m , Cycle : 5 Attenuation Increase:≤0.1dB
Repeated Bend IEC 794-1-E6 Bending Radius : X 20D, Cycle : 30 Attenuation Increase:≤0.1dB
Torsion IEC 794-1-E7 Length : 1m, Torsion angle : ±180, Cycle:20 Attenuation Increase:≤0.1dB
Temp. Cycling IEC 794-1-F1 Step:+20°C->-20°C°C->+60°C->+20°C, 24Hrs Attenuation Increase:≤0.1dB/km