Fiber Optic Cable |
Cable Cross Section |
|
|
x is Number of Cores & X<= 48 |
 |
Loose Tube Fiber Optic Cable SM, 2~ 48C,
Single Jacket,
Two Wire Steel,
Corrugated Steel Armored |
Application :
Duct, Aerial, Direct Buried |
|
|
|
Cable Construction & Description
|
| |
|
| Fiber
Coloring : |
UV Curable Acrylic Color
Ink |
| No.
of Tube : |
1Tubes |
| No.
of fiber/Tube : |
Max. 48 Fibers |
| Loose
Tube Material : |
PBT |
| Filling
compound (Tube) : |
Thixotropic Jelly |
| Strength Member : |
Steel Wire(Nom.1.2mm
Dia. * 2c) |
| Water
Blocking : |
Water Swell able Material |
| Corrugated
Steel Tape : |
Nom. O.25mm Thick. |
| Outer
Sheath : |
Nom. 2.7mm Thick. Black MDPE, Anti Rodent
outer sheath protect cable from Ultra
Violet radiation |
| Cable
Marking : |
Cable type, Fiber Counts |
|
Name of Manufacturer |
|
Year of Manufacturing, |
|
Cable Length in meter |
| Cable
Outside Diameter : |
Nom. 10.2mm ~
15.0 mm |
| Cable
Weight : |
Approx. 120 kg/km
~ 200 kg/km |
| Packing
: |
Export Wooden Drum |
|
Bending Radius : |
Static: 10D (Diameter of cable) |
| |
Dynamic: 20D (Diameter of cable) |
| |
|
Optical Fiber Performance |
| |
| 1.Optical
& Geometrical Performance |
| |
|
|
| |
Mode Field Diameter
: |
9.2 ± 0.4 μm at 1310 nm |
| |
Mode Field Concentricity
Error : |
≤ 0.8μm |
| |
Cladding Diameter : |
125 ± 1μm |
| |
Cladding Non-Circularity: |
≤ 1% |
| |
Coating Diameter : |
245 ± 10μm |
| |
Coating Non-Circularity
Error : |
≤ 6% |
| |
Attenuation Coefficient
: |
≤ 0.36dB/km at 1310nm |
| |
|
≤ 0.22dB/km at 1550nm |
| |
Chromatic Dispersion
: |
≤3.5ps/nm/km at1285~1330nm |
| |
|
≤18ps/nm/km at 1550nm |
| |
Cut-off Wavelength
(λcc) : |
≤ 1260nm |
| |
Zero Dispersion Wavelength
: |
1300~1322nm |
| |
PMD Coefficient : |
≤ 0.2ps/√km |
| |
Point Discontinuity
: |
≤ 0.05 dB at 1310 & 1550nm |
| |
Effective Group Index
of : |
1.4677 at 1310nm(Typical) |
| |
Refraction (Neff) : |
1.4682 at 1550nm(Typical) |
| |
Type of Fiber Core: |
MCSM |
| |
| 2.Mechanical
& Environmental Performance |
| |
| |
Proof Test Level : |
≥ 0.69 GPa(≥100kpsi) |
| |
Macro bending : |
≤ 0.05 dB at 1550nm |
| |
(at 75mm dia. x100 turns) |
| |
Temperature Dependence
: |
≤ 0.05 dB/km at 1550nm |
| |
(-60°C to 85°C) |
| |
Damp Dependence: |
≤ 0.05 dB/km at 1550nm |
| |
(+80°C,85%RH for 30Days) |
| |
Water soak Dependence
: |
≤ 0.05 dB/km at 1550nm |
| |
(+20°C for 30Days) |
| |
|
Identification of optical fiber & Loose Tube |
| |
|
Optical Fiber |
Loose Tube |
|
1 |
Blue |
7 |
Red |
White |
|
2 |
Orange |
8 |
Black |
|
3 |
Green |
9 |
Yellow |
|
4 |
Brown |
10 |
Violet |
|
5 |
Grey |
11 |
Pink |
|
6 |
White |
12 |
Aqua |
|
| |
|
Mechanical & Environmental Performance |
| |
|
Item |
Reference |
Test
Condition |
Acceptance Criteria |
|
Tensile Strength |
IEC 794-1-E1 |
Long Term : 1000N,
Short Term : 3000N |
Attenuation Increase:≤0.05dB |
|
Crush |
IEC 794-1-E3 |
Loading : 5000N/100mm |
Attenuation Increase:≤0.05dB |
|
Impact |
IEC 794-1-E4 |
Loading : 10N.m ,
Cycle : 5 |
Attenuation Increase:≤0.05dB |
|
Repeated Bend |
IEC 794-1-E6 |
Bending Radius : X 20D,
Cycle : 30 |
Attenuation Increase:≤0.05dB |
|
Torsion |
IEC 794-1-E7 |
Length : 1m,
Torsion angle : ±180,
Cycle:10 |
Attenuation Increase:≤0.05dB |
|
Cable Bend |
IEC 794-1-E11 |
Bending Radius : X 10D,
Cycle : 10, Turns:5 |
Attenuation Increase:≤0.05dB |
|
Temp. Cycling |
IEC 794-1-F1 |
Step: +20°C->-40°C°C->+70°C-
>+20°C, 24Hrs |
Attenuation Increase:≤0.1dB/km |
|
Water Penetration |
IEC 794-1-F5 |
Length : 1m,
Height : 1m,
Times : 24Hrs |
No Leakage |
|
| |